Product
All categories
Micro ultraviolet spectrophotometer
Model :MD3000
Product use:
1. Detection of nucleic acid concentration: detect the concentration of dsDNA, ssDNA, RNA and other nucleic acids at 200-900nm;
2. Probe detection: detect the absorbance value of the fluorescent labeled probe, which can be used to remove the sample that fails to label the probe;
3. Protein concentration detection: detect the concentration of common protein after purification;
4. Protein labeling detection: It can detect the protein concentration to be measured accurately by BCA, Bradford or Lowry, automatically draw the standard curve and calculate the concentration;
5. Detection of saccharides, aldehydes and other biological macromolecules: detect the absorbance value of samples under conventional ultraviolet light wave;
6. Detection of cell culture: detect the Abs of cell culture at 600 nm;
7. Kinetic detection: enzyme kinetics research, standard curve drawing.
Product features:
1. It has two detection modes: colorimetric plate and micro detection hole;
2. Detection wavelength range: 200-900nm;
3. Minimum sample size: 0.5 μ L samples can be tested;
4. Nucleic acid detection range: 2-15000ng/ul (dsDNA), which can be directly loaded for detection without concentration or dilution of samples;
5. Fast detection: results can be obtained in about 5s;
6. Convenient and fast detection: it can be used after startup without preheating;
7. Built-in 7-inch touch display screen can complete operation without computer;
8. CCE calibration technology can calibrate itself without return;
9. It can provide data traceability function in accordance with international standards.
Technical parameters:
Micro mode:
1. Minimum sample size: 0.5-1μl;
2. Wavelength range: 200-900nm;
3. Wavelength accuracy:<1nm;
4. Wavelength resolution:<1nm;
5. Light source: xenon lamp;
6. Optical path: 0.5, 0.25&0.05mm (automatic or manual adjustment);
7. Detection cycle: <5s;
8. Detector type: 2048 linear CCD array;
9. Detection range: 2ng/ul-15000ng/ul (dsDNA);
10. Light absorption range: 0.04-40A (10mm optical path);
11. Absorbance precision: 0.002 Abs (1 mm optical path);
12. Absorption accuracy: 1%;
13. Touch screen size: 7 inches;
14. Memory: 16GB;
15. Network interface: yes;
16. USB interface: 2;
17. Sample table material: 303 stainless steel and quartz fiber.
Cell mode
1. Specification of cuvette: 12.5 mm (L) x 12.5 mm (W) x 45 mm (H);
2. Optical path: 10, 5, 2&1 mm
3. Light column height: 8.5mm (from the bottom of the cuvette);
4. Temperature control accuracy: 37 ± 0.5 ℃;
5. Mixing speed: 130-900 RPM;
6. Detection range: 0.04 – 750 ng/ μ L (dsDNA)。
Standard configuration:
1. One host;
2. One manual;
3. One set of software;
4. One power cord;